[Top] [Prev] [Next] [Bottom]

Appendix A

Hardware Specifications


This appendix describes the physical characteristics, specifications, and requirements for the GTS 205 and GTS 250.

GTS 205 GTS 250
Dimensions
Height

43.7 mm (1.75 in) 87.4 mm (3.4 in)
Depth

254 mm (10 in) 305 mm (12 in)
Width

440 mm (17.25 in) 440 mm (17.3 in)
Weight 3.2 kg (7 lb) 5.16 kg (11.4 lb)-Unit without adapter enablement feature 5.57 kg (12.5 lb)-Unit with adapter enablement feature
Operating Environment
Temperature

5º to 40.7º (41º to 105º F) See Note 1. 5º to 40.7º (41º to 105º F) See Notes 1 and 3.
Relative Humidity

8% to 80% 8% to 80%
Maximum wet bulb

26.7º C (80º F) See Note 2. 26.7º C (80º F) See Note 2.
GTS 205 GTS 250
Power Source Loading 100 VA maximum 200 VA maximum
Maximum Current .8A at 100V .4A at 240V 2A at 100V 1A at 240V
Power Supply 35 watts 35 watts
Operating Voltage 100 to 250 Vac 100 to 250 Vac
Operating Clearance
Front

76 cm (30 in) 76 cm (30 in)
Rear

15 cm (6 in) 15 cm (6 in)
Service Clearance
For placement with cables at the front

Front: 76 cm (30 in) Front: 76 cm (30 in)
For placement with cables at the rear

Front: 76 cm (30 in) Rear: 76 cm (30 in) Left: 76 cm (30 in) Right: 76 cm (30 in) Front: 76 cm (30 in) Rear: 76 cm (30 in) Left: 76 cm (30 in) Right: 76 cm (30 in)

Notes:

1. The upper temperature limit must be lowered 1º C for every 137 meters of elevation above 915 meters.
2. The upper wet bulb temperature must be lowered 1º C for every 274 meters of elevation above 305 meters.
3. The GTS 250 contains a temperature sensor which reads the temperature inside the router. Do not confuse readings you see there with the ambient temperature values. The temperature inside the enclosure will be higher. This is normal.


[Top] [Prev] [Next] [Bottom]

docs@openroute.com
Copyright © 1998, OpenROUTE Networks, Inc. All rights reserved.