This procedure assumes you have the following:
The operating software on the 3000 Series is Release 5.1.0 or later.
The 3000 voice software is r01.00.00 and has a working database.
A PC that has access to the new 3000 voice software and is running the NetrixView 2000 application, and you are familiar with using this application.
The IP address of the voice module, and the ability to access the voice module using FTP.
A basic understanding of FTP file transfers.
Checking Amount of Free Space on Voice Module
We recommend that you check the amount of free space on the Analog Voice Module's Flash File System prior to transferring new files to the module. If the module runs out of free space before a file completes transferring, the voice module resets.
bootrom.bin 606076 Jul 19 10:41
uaiemtbl.bin 67,760 Jul 19 10:42
uaitable.bin 745,360 Jul 19 10:42
xps_850.Z 1,774,439 Jul 19 10:45
xps_850.gd 659,218 Jul 19 10:45
xps_850.ge 445,623 Jul 19 10:45
xps_850.gh 536,087 Jul 19 10:45
copy the new bootrom file to the voice module and then
use the NetrixView 2000 software to install the new software on the voice module.
restart the router.
To copy the new software to the voice module:
c:cd r1_1_0\
c:\r1_1_0>ftp 192.168.1.2
The software prompts you for the User and Password. The user is "netrix" and the password is "techtech."
User: netrix
Password:techtech
Note: This step is VERY IMPORTANT.
ftp>binary
ftp>hash
Hash mark printing On <2048 bytes/hash mark>.
ftp>cd /ata0/sys/test.rel/xps
ftp>put bootrom.bin
Note that this file is large, so the put command may take several minutes to complete. The hash feature lets you follow the progress of the file transfer with the printing of # characters.
ftp> bye
To install the boot code, use the NetrixView 2000 software:
The software immediately informs you that it is done, but you must wait at least 15 seconds.
* restart
Are you sure you want to restart the gateway? (Yes or [No]): y
c:cd r1_1_0\
c:\r1_1_0>ftp 192.168.1.2
The software prompts you for the User and Password. The user is "netrix" and the password is "techtech."
User: netrix
Password:techtech
ftp>binary
ftp>hash
Hash mark printing On <2048 bytes/hash mark>.
ftp> cd /ata0/sys/
ftp> mkdir r1_1_0 [or similar, based on the software upgrade rev.]
ftp> cd r1_1_0
ftp> mkdir xps
ftp> cd xps
ftp> put bootrom.bin
ftp> put uaiemtbl.bin
ftp> put uaitable.bin
ftp> put xps_850.gd
ftp> put xps_850.ge
ftp> put xps_850.gh
ftp> put xps_850.Z
(For convenience, you can use the mput command to put multiple files per command line.)
ftp>bye
To cause the Voice Module Processor to boot using the new software, restart the 3000 Series using the command line interface:
* restart
Are you sure you want to restart the gateway? (Yes or [No]): y
xps 850 Nx3000-r01.01.00 Wed Jul 19 08:39:43 2000
/Nx3000Boot-r01.01.00/xps_850WedJul1908:11:142000352000