ELS Messages for Environment Functions (ENV)
- Level:
- C-TRACE
- Short Syntax:
- ENV.001 current temp temperature_celsius
C ( temperature_fahrenheit
F)
- Long Syntax:
- ENV.001 Current ambient temperature: temperature_celsius
C ( temperature_fahrenheit
F)
- Description:
- The router generates this message each time it recalculates
the current ambient temperature.
- Level:
- U-TRACE
- Short Syntax:
- ENV.002 hi temp thresh active: threshold_temperature_celsius
C ( threshold_temperature_fahrenheit
F)
- Long Syntax:
- ENV.002 High temperature threshold is active. Threshold: threshold_temperature_celsius
C ( threshold_temperature_fahrenheit
F)
- Description:
- Trace message indicating that the router passed the high temperature
threshold and the high temperature threshold is active. The router
generates this message each time it recalculates the current ambient
temperature and the current ambient temperature surpasses the high
temperature threshold.
- Level:
- U-TRACE
- Short Syntax:
- ENV.003 low temp thresh active: threshold_temperature_celsius
C ( threshold_temperature_fahrenheit
F)
- Long Syntax:
- ENV.003 Low temperature threshold is active. Threshold: threshold_temperature_celsius
C ( threshold_temperature_fahrenheit
F)
- Description:
- Trace message indicating that the router passed the low temperature
threshold and the low temperature threshold is active. The router
generates this message each time it recalculates the current ambient
temperature and the current ambient temperature is below the low
temperature threshold.
- Level:
- UE-ERROR
- Short Syntax:
- ENV.004 hi temp thresh exceeded: threshold_temperature_celsius
C ( threshold_temperature_fahrenheit
F)
- Long Syntax:
- ENV.004 High temperature threshold has been exceeded. Threshold: threshold_temperature_celsius
C ( threshold_temperature_fahrenheit
F)
- Description:
- Trace message indicating that the router passed the high temperature
threshold and the high temperature
threshold is active. The router generates this message when it first
detects that the high temperature condition is active.
If the ambient temperature of the router exceeds its stated
operational maximum (set at the factory, independent of the configured
high temperature threshold), it automatically shuts down
until the ambient temperature returns to within its
stated operational range. This prevents damage to the router and
the data flow.
- Cause:
- The value of the high temperature threshold is configured too low for
the site's average operational ambient temperature.
- Action:
- Verify that the high temperature threshold is set to the correct
desired temperature, in consideration of the particular site's normal
ambient temperature range.
- Cause:
- Possible failure of the router's internal fan.
- Action:
- Verify the operation of the router's internal fan. If the internal
fan is not operational, contact customer service.
- Cause:
- Possible failure of the environmental control system of the site where
the router resides.
- Action:
- Verify the operation of the site's environmental control system.
- Level:
- UE-ERROR
- Short Syntax:
- ENV.005 low temp thresh exceeded: threshold_temperature_celsius
C ( threshold_temperature_fahrenheit
F)
- Long Syntax:
- ENV.005 Low temperature threshold has been exceeded. Threshold: threshold_temperature_celsius
C ( threshold_temperature_fahrenheit
F)
- Description:
- Trace message indicating that the router passed the low temperature
threshold and the low temperature
threshold is active. The router generates this message when it
first detects that the low temperature condition is active.
- Cause:
- The value of the low temperature threshold is configured too high for
the site's average operational ambient temperature.
- Action:
- Verify that the low temperature threshold has been set to the correct
desired temperature, with consideration of the site's normal ambient
temperature range.
- Cause:
- Possible failure of the environmental control system of the site where
the router resides.
- Action:
- Verify the operation of the site's environmental control system.