ELS Messages for BSC Spoofing (BSPF)


BSPF.001

Level:
UI-ERROR
Short Syntax:
BSPF.001 Invalid configuration with ip addr cnfgd on nt networkID
Long Syntax:
BSPF.001 Invalid router configuration because an IP address has been configured on network networkID
Description:
IP addresses are not allowed to be configured on the BSC Spoofing interfaces.

BSPF.002

Level:
UI-ERROR
Short Syntax:
BSPF.002 Unsupported intf nt networkID
Long Syntax:
BSPF.002 Unsupported interface on network networkID
Description:
An unsupported network interface had been configured on the BSC Spoofing group.

BSPF.003

Level:
C-INFO
Short Syntax:
BSPF.003 BSC Spoofing intf initialization started nt networkID
Long Syntax:
BSPF.003 BSC Spoofing initialization started on network networkID
Description:
The BSC Spoofing forwarder began initialization on the interface.

BSPF.004

Level:
C-INFO
Short Syntax:
BSPF.004 BSC Spoofing intf init completed nt networkID
Long Syntax:
BSPF.004 BSC Spoofing initialization completed on network networkID
Description:
The BSC Spoofing forwarder completed initialization on the interface.

BSPF.005

Level:
UI-ERROR
Short Syntax:
BSPF.005 Discard scndry->prmry pkt addr BSPF_addr H net congestd on nt networkID
Long Syntax:
BSPF.005 Discard BSPF frame with BSC address BSPF_addr H heading to primary station due to network congestion on network networkID
Description:
A Sec->Pri BSPF frame had been discarded out a network interface due to congestion.
Cause:
Bursty traffic may be causing outbound frame congestion or internal software inconsistancies exists. check bridge configuration.

BSPF.006

Level:
C-TRACE
Short Syntax:
BSPF.006 Added prmry->scndry pkt addr BSPF_address H to BSPF queue
Long Syntax:
BSPF.006 Added packet received on primary side with BSC address BSPF_address H onto the BSPF queue.
Description:
This message is generated whenever the forwarder receives a BSC Spoofing frame from a primary port (port directly or indirectly attached to a primary station) destined for a secondary port (port directly or indirectly attached to a secondary station).

BSPF.007

Level:
C-TRACE
Short Syntax:
BSPF.007 added scndry->prmry pkt addr BSPF_address H to BSPF queue
Long Syntax:
BSPF.007 Added packet received on secondary side with BSPF address BSPF_address H onto the BSPF queue.
Description:
This message is generated whenever the forwarder receives a BSC Spoofing frame from a secondary port (port directly or indirectly attached to a secondary station) destined for a primary port (port directly or indirectly attached to a primary station).

BSPF.008

Level:
CE-ERROR
Short Syntax:
BSPF.008 frm disc group group_num not defined nt networkID
Long Syntax:
BSPF.008 A BSC Spoofing frame discarded due to group group_num defined in the frame received from the network networkID not being defined in the router.
Description:
A BSC Spoofing frame has been discarded due to the group number of the frame not being defined for that router.

BSPF.009

Level:
CE-ERROR
Short Syntax:
BSPF.009 Frame discarded because group group_num is disabled nt networkID
Long Syntax:
BSPF.009 A BSC Spoofing frame discarded due to group group_num being disabled for frame coming in from the network networkID .
Description:
A BSC Spoofing frame has been discarded due to the group not being enabled.

BSPF.010

Level:
CE-ERROR
Short Syntax:
BSPF.010 Frame with BSC addr BSPF_addr H group group_num disc src primary port disabled
Long Syntax:
BSPF.010 A BSC Spoofing frame with BSC address BSPF_addr H discarded due to the source primary port of group group_num being disabled.
Description:
A BSC Spoofing frame has been discarded due to the source port's (where the frame was coming from) being disabled.

BSPF.011

Level:
CE-ERROR
Short Syntax:
BSPF.011 Frame discarded because dev cu_num not defined nt networkID
Long Syntax:
BSPF.011 A BSC Spoofing frame discarded due to control unit cu_num defined in the frame received from the network networkID not being defined in the router.
Description:
A BSC Spoofing frame discarded due to control unit number defined in the frame received from the network interface not being defined in the that router.

BSPF.012

Level:
CI-ERROR
Short Syntax:
BSPF.012 Frame discarded src prt BSC addr BSPF_addr H not found in group group_num
Long Syntax:
BSPF.012 A BSC Spoofing frame discarded due to the src port with BSC address BSPF_addr H specified in the frame not being found in group group_num .
Description:
A BSC Spoofing frame has been discarded due to the src port with the BSC address specified in the frame not being found in the group specified. This is a result of user misconfiguration of the group.

BSPF.013

Level:
CI-ERROR
Short Syntax:
BSPF.013 Frame with BSC addr BSPF_addr H group group_num disc because dst primary port disabled
Long Syntax:
BSPF.013 A BSC Spoofing frame with BSC address BSPF_addr H discarded due to the destination primary port of group group_num being disabled.
Description:
A BSC Spoofing frame has been discarded due to the destination port (where the frame was heading to) being disabled.

BSPF.014

Level:
CI-ERROR
Short Syntax:
BSPF.014 Frame discarded prt dst BSC addr BSPF_addr H not fnd in group group_num
Long Syntax:
BSPF.014 A BSC Spoofing frame discarded due to the destination port BSC address BSPF_addr H specified in the packet not being found in group group_num .
Description:
A BSC Spoofing frame has been discarded due to the destination port with the BSC address specified in the frame not being found in the group specified. This is a result of user misconfiguration of the group. The specific port with BSC address %d was not added to the group.

BSPF.015

Level:
CI-ERROR
Short Syntax:
BSPF.015 A frm with dst BSC addr BSPF_addr H discarded; rly dwn or rly disabled networkID
Long Syntax:
BSPF.015 BSPF frame with dst BSC addr BSPF_addr H discarded due to down condition on network networkID
Description:
A BSPF frame had been discarded due to the BSC Spoofing failing to forward out a network interface which had been in a down state. This message will be printed if the network is down or if IP is not not currently enabled; if IP is not enabled, no BSC Spoofing can take place, so the frame is simply discarded.

BSPF.016

Level:
CI-ERROR
Short Syntax:
BSPF.016 A discarded scndry->prmry frame BSC addr BSPF_addr H rjd rsn = reason on nt networkID
Long Syntax:
BSPF.016 discard net rejected BSPF frame address BSPF_addr H heading for primary station with reject reason = reason on network networkID
Description:
A BSC Spoofing frame has rejected by the network interface and discarded.

BSPF.017

Level:
P-TRACE
Short Syntax:
BSPF.017 Discard frame src_BSPF_addr H -> dst_BSPF_addr H nt networkID
Long Syntax:
BSPF.017 Discarded frame with source addr src_BSPF_addr H and destination addr dst_BSPF_addr H on network networkID
Description:
A frame had been discarded due to BSC Spoofing not configured on interface noted.
Cause:
The null or fake forwarder is configured on the interface, all received BSC Spoofing frames are discarded.

BSPF.018

Level:
C-INFO
Short Syntax:
BSPF.018 Forwarded BSPF from scndry->prmry BSC addr BSPF_addr H nt networkID
Long Syntax:
BSPF.018 Forwarded BSC Spoofing frame from secondary station destined for primary station with frame BSC address BSPF_addr H on network networkID
Description:
A frame traveling in the direction of secondary->primary station has been forwarded out onto the interface noted.

BSPF.019

Level:
C-INFO
Short Syntax:
BSPF.019 Forwarded BSPF from prmry->scndry BSC addr BSPF_addr H nt networkID
Long Syntax:
BSPF.019 forwarded BSC Spoofing frame from primary station destined for secondary station with frame BSC address BSPF_addr H on network networkID
Description:
A frame traveling in the direction of primary->secondary station has been forwarded out onto the interface noted.

BSPF.020

Level:
UI-ERROR
Short Syntax:
BSPF.020 Discard from from nt networkID ; IP not enabled
Long Syntax:
BSPF.020 Discard BSPF frame from network networkID because IP is not enabled on router
Description:
A BSC Spoofing frame has discarded. In order for BSC Spoofing to work, IP has to be enabled on the router. The user must add at least one IP address to at least one of its non-BSC Spoofing interfaces.

BSPF.021

Level:
CI-ERROR
Short Syntax:
BSPF.021 Received block with bad crc from nt networkID
Long Syntax:
BSPF.021 A block with a bad CRC was received from network networkID .
Description:
A BSC block has been received with a bad CRC by the network interface and discarded. Normal protocol procedures should recover. Excessive CRC errors indicate transmission line problems.

BSPF.022

Level:
CI-ERROR
Short Syntax:
BSPF.022 Discarded frame because group group_num cnfg bad
Long Syntax:
BSPF.022 Frame discarded because group group_num configuration is bad.
Description:
This message is generated when the forwarder must discard a packet because the group configuration among the routers participating in BSC Spoofing are inconsistent with each other. Check to make sure the primary and secondary attributes of the ports in groups are consistent.

BSPF.023

Level:
C-TRACE
Short Syntax:
BSPF.023 Data blk good crc from nt networkID
Long Syntax:
BSPF.023 A block with a good CRC was received from network networkID .
Description:
This message is generated whenever a BSC data block is successfully received from the BSC line.

BSPF.024

Level:
CI-ERROR
Short Syntax:
BSPF.024 Discard prmry->scndry pkt addr BSPF_addr H net congestd on nt networkID
Long Syntax:
BSPF.024 Discard BSPF frame with BSC address BSPF_addr H heading to secondary station due to network congestion on network networkID
Description:
A Pri->Sec BSPF frame had been discarded out a network interface due to congestion.
Cause:
Bursty traffic maybe causing outbound frame congestion or internal software inconsistancies exists. check bridge configuration.

BSPF.025

Level:
CI-ERROR
Short Syntax:
BSPF.025 Frame with BSC addr BSPF_addr H group group_num disc src scndry port dsbld
Long Syntax:
BSPF.025 A BSC Spoofing frame with BSC address BSPF_addr H discarded due to the source secondary port of group group_num being disabled.
Description:
A BSC Spoofing frame has been discarded due to the source port(where the frame was coming from) being disabled.

BSPF.026

Level:
CI-ERROR
Short Syntax:
BSPF.026 Frame with BSC addr BSPF_addr H group group_num disc dst scndry port dsbld
Long Syntax:
BSPF.026 A BSC Spoofing frame with BSC address BSPF_addr H discarded due to the destination secondary port of group group_num being disabled.
Description:
A BSC Spoofing frame has been discarded due to the destination port (where the frame was heading to) being disabled.

BSPF.027

Level:
CI-ERROR
Short Syntax:
BSPF.027 Discard prmry->scndry frm BSC addr BSPF_addr H rjd rsn = reason on nt networkID
Long Syntax:
BSPF.027 Discard net rejected BSC frame address BSPF_addr H heading for secondary station with reject reason = reason on network networkID
Description:
A BSC Spoofing frame has rejected by the network interface and discarded.

BSPF.028

Level:
C-TRACE
Short Syntax:
BSPF.028 Sending activate dev cu_addr to rmt
Long Syntax:
BSPF.028 Sendind Activate Device cu_addr Request to Remote End.
Description:
The Primary end has detected polls for an inactive device and is sending an activate request to the Secondary end to begin polling.

BSPF.029

Level:
CI-ERROR
Short Syntax:
BSPF.029 No rsp dev cu_addr nt networkID
Long Syntax:
BSPF.029 Device cu_addr on network networkID is not responding to polls.
Description:
The BSC control unit configured on the network is not responding to polling.

BSPF.030

Level:
CI-ERROR
Short Syntax:
BSPF.030 Err xmt to dev cu_addr nt networkID
Long Syntax:
BSPF.030 Interface error sending block to device cu_addr on network networkID .
Description:
The local network interface was unable to transmit a block to the local BSC control unit configured on the network.

BSPF.031

Level:
P-TRACE
Short Syntax:
BSPF.031 Actvating dev cu_addr nt networkID
Long Syntax:
BSPF.031 Activating device cu_addr on network networkID .
Description:
BSC Spoofing is activating local device for polling or responding.

BSPF.032

Level:
P-TRACE
Short Syntax:
BSPF.032 Rx Xoff dev cu_addr nt networkID
Long Syntax:
BSPF.032 Received Xoff for device cu_addr on network networkID .
Description:
BSC Spoofing has received an Xoff flow control request from the remote end for this local device.

BSPF.033

Level:
P-TRACE
Short Syntax:
BSPF.033 Rx Xon dev cu_addr nt networkID
Long Syntax:
BSPF.033 Received Xon for device cu_addr on network networkID .
Description:
BSC Spoofing has received an Xon flow control request from the remote end for this local device.

BSPF.034

Level:
P-TRACE
Short Syntax:
BSPF.034 Frm dsc nt act dev cu_addr nt networkID
Long Syntax:
BSPF.034 A data block received from the remote for device cu_addr on network networkID was discarded because the device was not active.
Description:
BSC Spoofing has received a data frame for the local device, but the local device is not activated. The frame is discarded.

BSPF.035

Level:
C-TRACE
Short Syntax:
BSPF.035 bsc tcp fclos int networkID
Long Syntax:
BSPF.035 BSC TCP force close interface networkID
Description:
A TCP connection is in process of being force closed.

BSPF.036

Level:
C-INFO
Short Syntax:
BSPF.036 Forwarded BSPF frm addr BSPF_addr H to TCP
Long Syntax:
BSPF.036 Forwarded BSC Spoofing frame BSC address BSPF_addr H to TCP
Description:
A frame has been forwarded out to the TCP connection.

BSPF.037

Level:
CI-ERROR
Short Syntax:
BSPF.037 Discard frm BSC addr BSPF_addr H no TCP conn
Long Syntax:
BSPF.037 BSC frame with frame BSC address BSPF_addr H discarded because the TCP connection was lost
Description:
A frame traveling to the remote end has been discarded because the TCP connection has been lost.

BSPF.038

Level:
C-INFO
Short Syntax:
BSPF.038 Frame BSC addr BSPF_addr H to TCP holdq
Long Syntax:
BSPF.038 BSC frame with frame BSC address BSPF_addr H has been put on the TCP holding queue because TCP has no room to transmit it.
Description:
A frame traveling to the remote end has been held because the TCP connection has been filled up.

BSPF.039

Level:
C-INFO
Short Syntax:
BSPF.039 Sending Xoff to rmt(s)
Long Syntax:
BSPF.039 Xoff requests are being sent to remotes due to local congestion on the BSC queue.
Description:
The local BSC device is not keeping up with the data flow from the remotes, so flow control off requests are sent to remote(s).

BSPF.040

Level:
C-INFO
Short Syntax:
BSPF.040 Sending Xon to remote(s)
Long Syntax:
BSPF.040 Xon requests are being sent to remotes due to the clearing of local congestion on the BSC queue.
Description:
The local BSC device has accepted enough data to allow the remotes to again send data, so flow control on requests are sent to the remote(s).

BSPF.041

Level:
C-INFO
Short Syntax:
BSPF.041 Unable to alloc mem for ctrl msg - addr BSPF_addr H nt networkID
Long Syntax:
BSPF.041 The BSPF forwarder failed to allocate sufficient memory to be used in sending a control flow message - BSC address BSPF_addr H on network networkID
Description:
The BSPF forwarder failed to allocate sufficient memory to be used in sending a control flow message. The interface is being disabled.

BSPF.042

Level:
C-INFO
Short Syntax:
BSPF.042 TCP act opn nt networkID
Long Syntax:
BSPF.042 A TCP active open was initiated on network networkID
Description:
A TCP open command has been sent to the destination.

BSPF.043

Level:
C-INFO
Short Syntax:
BSPF.043 TCP clos nt networkID
Long Syntax:
BSPF.043 A TCP close was initiated on network networkID
Description:
A TCP close has been started.

BSPF.044

Level:
C-INFO
Short Syntax:
BSPF.044 TCP tmo nt networkID
Long Syntax:
BSPF.044 A TCP timeout has occurred on network networkID
Description:
A TCP connection timeout has has occurred.

BSPF.045

Level:
CI-ERROR
Short Syntax:
BSPF.045 TCP wrq empty nt networkID
Long Syntax:
BSPF.045 A TCP write attempted with empty queue network networkID
Description:
A TCP write was attempted but the write queue is empty.

BSPF.046

Level:
C-INFO
Short Syntax:
BSPF.046 TCP tcb read nt networkID
Long Syntax:
BSPF.046 A TCP read of the tcb was started network networkID
Description:
A TCP read of the tcb was started indicating call data processing.

BSPF.047

Level:
C-INFO
Short Syntax:
BSPF.047 TCP rd of rx blk nt networkID
Long Syntax:
BSPF.047 A TCP write attempted with empty queue network networkID
Description:
A TCP write was attempted but the write queue is empty.

BSPF.048

Level:
CI_ERROR
Short Syntax:
BSPF.048 Mem alloc fail nt networkID
Long Syntax:
BSPF.048 A memory allocation request has failed for network networkID
Description:
A memory allocation request for a critical resource has failed.

BSPF.049

Level:
C-INFO
Short Syntax:
BSPF.049 TCP pass opn nt networkID
Long Syntax:
BSPF.049 A TCP passive open was initiated on network networkID
Description:
A TCP passive open has been on the specified interface and network.

BSPF.050

Level:
C-INFO
Short Syntax:
BSPF.050 TCP pass opn fail nt networkID
Long Syntax:
BSPF.050 A TCP passive open was initiated which failed on network networkID
Description:
A TCP passive open attempt has failed on the specified interface and network.

BSPF.051

Level:
C-TRACE
Short Syntax:
BSPF.051 Buf err iob BSPF_iorb H nt networkID
Long Syntax:
BSPF.051 A buffer error has been detected in iob BSPF_iorb H on network networkID
Description:
A buffer error has been detected on the specified iorb, network and interface.

BSPF.052

Level:
CI-ERROR
Short Syntax:
BSPF.052 grp group type err nt networkID
Long Syntax:
BSPF.052 The BSPF group group net type or interface type is wrong, port is disabled for net type networkID
Description:
A BSC relay frame destined for a far router has been discarded because interface type is wrong or port is disabled.
Panic
BSPFimem
Short Syntax:
BSPF mem alloc failed\r\n
Description:
The BSPF forwarder failed to allocate sufficient memory to complete initialization.
Action:
Contact customer service.
Panic
BSPFudperr
Short Syntax:
BSPF udp port not avail\r\n
Description:
Another application registered previously with BSPF's UDP port.
Action:
Contact customer service.